Warning Message
"Tolerance
exceeded!"
7.4.4
Line
LS10/LS15, Programs
Option
Description
F1
If you select F1 Remeasure last station (1), the instrument assumes
that all staff ground points are clearly identified and unchanged. All
prior measurements for this station are deleted and have to be
remeasured.
If you select F2 Repeat last measurement (2), only the last measure-
F2
ment for this station is deleted and has to be remeasured.
If you select F4 Accept (4), the instrument ignores the warning
F4
message and stores the measurement.
Setting a Line and a Method
Field
Description
Name of the current line.
Name
If the job is empty, a new line name is automatically created and
displayed.
Select a levelling method:
Method
• BF: Backsight and foresight are measured according to the
• BFFB: Backsight and foresight are measured according to the
• BBFF: Backsight and foresight are measured according to the
• BFBF: Backsight and foresight are measured according to the
• aBF: Backsight and foresight are measured alternatingly
• aBFFB: Backsight and foresight are measured alternatingly
• aFBBF: Backsight and foresight are measured alternatingly
Example of warning message screen. The
title of the screen describes which type
of tolerance has been exceeded, e.g. the
distance tolerance.
New or List
Set
pattern BF BF.
pattern BFFB BFFB.
pattern BBFF BBFF.
pattern BFBF BFBF.
according to the pattern BF FB BF FB.
according to the pattern BFFB FBBF BFFB.
according to the pattern FBBF BFFB FBBF.
New: To create a line. Only available if
the job already contains one or more
lines.
List: To view a list of available points
within the job. Only available if you
create a line or if the job contains no
line at all.
To set the selected line and method
and continue with the program.
57