Measurements - Leica LS10 User Manual

Digital level
Hide thumbs Also See for LS10:
Table of Contents

Advertisement

Digital Compass
(only LS15)
Overview Camera
(only LS15)
Interfaces
17.2
Height

Measurements

Distance
Measurements
Measurement Time
LS10/LS15, Technical Data
Working range:
Accuracy:
Correction of Declination:
Sensor:
Focal length:
Field of view:
Frame rate:
Focus:
Image storage:
Zoom:
White balance:
Brightness:
• RS232 Serial (only LS15)
• Bluetooth Serial
• Lemo USB for Active Sync/Mobile Device Centre connection (only LS15)
• Mini USB for Active Sync/Mobile Device Centre connection
• USB Host (for USB Stick)
Measurements
Standard deviation per km double run (ISO 17123-2):
Electronic measurement with invar staff
Electronic measurement with standard staff
Optical measurement
Standard Deviation:
For distances up to 50 m
For distances up to the maximal possible meas-
urement distance
500 ppm is 1 cm standard deviation at 20 m distance.
Measuring Range for Electronic Measurements:
Staff lengths
3 m to 4 m
3 m invar staff
2.7 m
1.82 m / 2 m
Typically 2.5 seconds.
360°/400 gon
2.7°/3 gon
5 Megapixel CMOS sensor
34 mm
6° x 4.8° (7.7° diagonal)
up to 20 frames per second
3 m (10 ft) to infinity at zoom level 1x
QVGA screenshot in *.bmp format
4-step (1x, 2x, 4x, 8x)
Automatic
Automatic
LS10/LS15
0.3 mm
0.3 mm
1.0 mm
2.0 mm
LS10
500 ppm
1000 ppm
Measuring Range
1.8 m - 110.0 m
1.8 m - 60.0 m
1.8 m - 100.0 m
1.8 m - 60.0 m
LS15 0.2 mm
0.2 mm
1.0 mm
2.0 mm
LS15
500 ppm
1000 ppm
101

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ls15