Foresight Display
LS10/LS15, Programs
Step
Description
OUT :: Difference from entered distance (positive value). The distance
between instrument and staff is too small.
IN :: Difference from entered distance (negative value). The distance
between instrument and staff is too big.
When the difference is greater than 0.5 m, a black arrow indicates
whether the measured distance is too small or too big.
When the difference is less than 0.5 m, a red arrow indicates
whether the measured distance is smaller or greater than the
entered value.
When the difference is less than 0.03 m, a green checkmark is
displayed.
4.
Move the staff according to the displayed value and take a new measure-
ment. Repeat this step until the measured distance corresponds to the
entered distance.
Before measuring the foresight point, you can edit the following fields:
Foresight Pt
Rem.
Press the trigger key to measure the foresight point. The measured values are
displayed in the fields Height FS, dH, Staff and Distance.
Focus
To automatically focus the telescope
(only LS15).
Rec
To save the measured values and
switch to the backsight screen.
SetOut
To switch to the Set Out Height
screen.
INT
To survey intermediate points.
The default value is 1. You can enter a point ID or change the
default value in the Point ID & Incrementation screen. The
ID of the foresight point is incremented automatically
according to the definitions of the Point ID & Incrementa-
tion screen (refer to " Define a Default Point ID and Incre-
mentation").
You can define an individual point ID for the next
point measured. Refer to "Apply an Individual Point
ID during measurements" (within "7.1.3 Point ID &
Incrementation").
Additional Remarks concerning the measurement (optional).