Leica RS232 Default
Settings
Pin Assignments
(only LS15)
LS10/LS15, Settings
Field
Description
Parity :
Even
Odd
None
Endmark :
CR/LF
CR
Stop bits: 1
Acknowlge: On
Off
For Mean, Mean S and Median, you only have to send the
acknowledgement character "?" after the mean/median value is
received, not for the individual measurement generating this
mean/median value.
When you select Default, the communication parameters are reset to the Leica RS232
default settings:
• 115200 Baud, 8 Databit, No Parity, CR/LF Endmark, 1 Stopbit.
1
2
7
8
3
6
4
5
PIN_001
Pin
Signal Name
1
USB_D+
2
USB_D-
3
GND
4
RxD
5
TxD
6
ID
7
PWR
8
NC
Even parity. Available if data bit is set to 7.
Odd parity. Available if data bit is set to 7.
No parity. Available if data bit is set to 8.
The terminator is a carriage return followed by a line
feed.
The terminator is a carriage return.
Number of bits at the end of a block of digital data.
Acknowledgement expected from other device after
data transfer received. If no acknowledgement is
returned, an error message displays.
No acknowledgement expected after data transfer.
Function
USB data line
USB data line
Signal ground
RS232, receive data
RS232, transmit data
Identification pin
Power input, nominal +12 V (11 V - 16 V)
Not connected
Direction
In or out
In or out
-
In
Out
In or out
In
-