Leica LS10 User Manual page 50

Digital level
Hide thumbs Also See for LS10:
Table of Contents

Advertisement

Set Out Distances
Step-by-Step
LS10/LS15, Programs
Step
Description
2.
Press the trigger key to take a measurement.
3.
Display field dH: Measured height difference.
Depending on the difference between entered and measured height differ-
ence, the following fields and graphical elements are displayed:
FILL :: Difference from entered height difference (positive value). The staff
is too low.
CUT :: Difference from entered height difference (negative value). The staff
is too high.
When the difference is greater than 0.2 m, a black arrow indicates
whether the measured height difference is above or below the
entered value.
When the difference is less than 0.2 m, a red arrow indicates
whether the measured height difference is above or below the
entered value.
When the difference is less than 0.01 m, a green checkmark is
displayed.
4.
Raise or lower the staff according to the displayed value and take a new
measurement. Repeat this step until the measured height difference corre-
sponds to the entered height difference.
Step
Description
1.
Enter the necessary data.
Pt ID: If desired, you can change the point ID. Default value is 1001. The
point ID is incremented after each measurement.
Rem.: If desired, enter a remark. When you enter a code, the field name
changes to Code.
SO D: Enter the distance that needs to be set out.
2.
Press the trigger key to take a measurement.
3.
Display field Dist: Measured distance.
Depending on the difference between entered and measured distance, the
following fields and graphical elements are displayed:
Back
To exit Set Out dH and return to the Set
Out Height screen.
SO dH
To display the Set Out dH screen.
50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ls15