3.4
Description
Icons
LS10/LS15, User Interface

Status Icons

The icons provide status information related to basic instrument functions.
Icon
Description
Tilt Check on LS15
Tilt Check is off. Tap the icon to open the Level & Tilt Check screen.
The instrument is levelled and Tilt Check is on. Tap the icon to open the
Level & Tilt Check screen.
Instrument needs to be levelled before a measurement can be performed.
Tap the icon to open the Level & Tilt Check screen.
Tilt Check on LS10
Instrument is levelled. Tap the icon to open the Level screen.
Instrument needs to be levelled. Tap the icon to open the Level screen.
Measurement Mode
Measurement mode is set to Single. Tap the icon to open the Mode
Settings screen.
Measurement mode is set to Mean. Tap the icon to open the Mode
Settings screen.
Measurement mode is set to Mean S. Tap the icon to open the Mode
Settings screen.
Measurement mode is set to Median. Tap the icon to open the Mode
Settings screen.
Measurement mode is set to Tracking. Tap the icon to open the Mode
Settings screen.
Orientation of Staff and Status of Earth Curvature Correction
Within the Check & Adjust application, the earth curvature correc-
tion is automatically set to On.
The orientation of the staff is set to upright. It is only possible to take
measurements with the 0-mark at the bottom of the staff. Tap the icon
to change the orientation to inverse.
The earth curvature correction is set to Off. Refer to "6.2 Regional
Settings" for details on how to set the earth curvature correction to On.
The orientation of the staff is set to inverse. It is only possible to take
measurements with the 0-mark at the top of the staff. The measured
values are negative. Tap the icon to change the orientation to upright.
The earth curvature correction is set to Off. Refer to "6.2 Regional
Settings" for details on how to set the earth curvature correction to On.
The orientation of the staff is set to upright. It is only possible to take
measurements with the 0-mark at the bottom of the staff. Tap the icon
to change the orientation to inverse.
The earth curvature correction is set to On. Refer to "6.2 Regional
Settings" for details on how to set the earth curvature correction to Off.
The orientation of the staff is set to inverse. It is only possible to take
measurements with the 0-mark at the top of the staff. The measured
values are negative. Tap the icon to change the orientation to upright.
The earth curvature correction is set to On. Refer to "6.2 Regional
Settings" for details on how to set the earth curvature correction to Off.
19