Leica LS10 User Manual page 115

Digital level
Hide thumbs Also See for LS10:
Table of Contents

Advertisement

Warnings and Errors
LS10/LS15, GSI Online Commands
Function
Spec. Command
Date and time:
19
d/m/y/min
Version
599
Message
Description
@W400
Instrument is busy Cause: Other device may be interfacing with
@W427
Invalid command
@E458
Tilt sensor is out of
range
@E439
No measurement
possible
Example
GET/n/WI19
Command: GET/M/WI19
Response: 19....+04271212
GET/n/WI599
Command: GET/M/WI599
Response: 599..6+00342673
Possible Cause / Action
the instrument.
Action: Check the interfacing priorities.
Cause: The string sent to the instrument
could not be decoded properly or command
does not exist.
Action: Check the syntax of the commands.
Check if buffer is over flow (maximum 100
characters).
Cause: Instrument out of level.
Action: Check if the instrument is set up and
levelled properly.
Cause:
• Insufficient or uneven lighting on the staff.
• Incorrect setup of the staff
(inverted/upright).
• The staff could be out of the telescope
field of view.
• The instrument may not be properly
focused onto the staff.
Action: Check and focus onto the staff with
optimum lighting. Ensure that the staff is set
up in its correct position.
115