6.5
Description
Access

Mode Settings

LS10/LS15, Settings
Mode Settings
In the Mode Settings screen you can select different measurement modes for single
or multiple measurements.
Multiple measurements: The instrument automatically carries out several measure-
ments in sequence until one of the following criteria is met:
• The defined number of measurements is reached.
• A terminating criterion is met.
• The procedure is terminated.
For all multiple measurement modes, the instrument stores the average measurement
values according to the mean or median selection and all individual measurements
contributing to this average.
1.
Select
Settings from the Main Menu.
2.
Select
Mode from the Settings Menu.
To quickly access the Mode Settings screen from within a program, tap on the
status icon
.
Field
Description
The instrument carries out a single measurement (n = 1).
Single
Enter the number of measurements to be made (n = 2...99).
Mean
The instrument calculates the average of all measurements.
Mode
To select a mode setting.
n Meas.
Only available for Mean or Median.
To set a number of measurements.
n Min.
Only available for Mean S.
To set a minimum number of measure-
ments.
n Max.
Only available for Mean S.
To set a maximum number of measure-
ments.
sDev/20m
Only available for Mean S.
To set a maximum standard deviation of
the average value at 20 m.