7.4.3
Set Tolerance
LS10/LS15, Programs

Setting Tolerances

Field
Description
When taking measurements near the edge of the staff, the
Precise :
reduced number of staff code elements may slightly lower the
measuring accuracy.
If Precise : is activated, the instrument monitors whether the
height reading is within 0.50 m to either end of the staff (top and
bottom). The top and bottom limits of the staff are automatically
converted to a 3 m Invar staff. In order to use different staff
lengths, you can manually adjust the limit values.
The precision mode also monitors critical distances between the
instrument and the staff. These distances depend on the physical
properties of the staff code. The measuring accuracy of height
measurements within these distance ranges may also be slightly
lower. A warning is displayed if the measuring distance is within
the following ranges: 13.250 m - 13.500 m and 26.650 m -
26.900 m. If the instrument detects a staff distance within these
ranges, slightly move the staff out of the mentioned measure-
ment range in order to maintain highest measurement accuracy
expectations.
Min.Distance:
If activated, the instrument monitors the minimum target
distance. If the tolerance is exceeded, a warning message is
displayed. For a detailed description of the warning message,
refer to the next paragraph " Warning Message "Tolerance
exceeded!"".
Change to the Values screen, to enter a value for the minimum
target distance.
To select an item of the list and to
activate or deactivate the selected
item, use the navigation keys.
Reset
To reset tolerances to default values.