Return Codes
LS10/LS15, GeoCom Commands
Name
DNA_GetMeasResult
DNA_SetRodPos
DNA_GetRodPos
DNA_StartMeasurement
DNA_StartAutofocus
DNA_GetTiltX
DNA_GetCompassData
DNA_GetTiltL
DNA_SwitchEarthCurvature
DNA_GetEarthCurvatureStatus %R1Q,29108:
DNA_GetJobNumber
DNA_WakeUpInstrument
DNA_SetStaffLength
DNA_GetStaffLength
Code
Description
0
OK
12032
Too dark or poor light.
12033
Too bright.
12034
Instrument not horizontal. Level up the instrument.
12035
Coarse correlation error. Too much coverage or insufficient code length.
12036
Fine correlation error. Too much coverage or insufficient code length.
12037
Distance outside the permitted range.
12038
Staff inverted or inverse mode activated.
12039
Bad focusing.
ASCII command
%R1Q,29005:7000
7000 is waittime in ms to make the measurement, in
reply the first argument is the height reading, the
second argument is the distance
%R1Q,29010:1
Parameter for normal staff is 0, parameter for
inverted staff is 1
%R1Q,29011:
%R1Q,29036:
%R1Q,29068:
%R1Q,29070:
%R1Q,29072:
%R1Q,29104:
%R1Q,29107:
Parameter 0 for Off, Parameter 1 for On
%R1Q,29109:
Number of stored jobs and codelists
%R1Q,29110:
To switch from stand-by mode to normal operation.
%R1Q,29127:
Parameter 0 for Automatic
Parameter 2 for Invar 3m (GPCL3)
Parameter 3 for Invar 2m (GPCL2)
%R1Q,29126:
Reply
%R1P,0,0:0,0.65493642920
7282,2.877974290086675,
91,53,5312137,0.01392063
4920635,20,1
%R1P,0,0:0
%R1P,0,0:0,1
%R1P,0,0:0
%R1P,0,0:0
%R1P,0,0:0,0.00075146
%R1P,0,0:0,1.70518667919
8458
%R1P,0,0:0,0.00068843
%R1P,0,0:0,22
%R1P,0,0:0,2