Survey Interme-
diate Points
SetOut Application
LS10/LS15, Programs
Additional Remarks concerning the measurement (optional).
Rem.
Start height
Height of the starting point. Default value is 0.00000 m.
If you select an already stored fixpoint as starting point, the field Start
height is automatically set to the height of the fixpoint.
To switch to the INT to BS display, press
Before taking a measurement:
Pt ID Int
After taking a measurement:
Staff
Distance
Height Int
dHt to BS
Pt ID lst Int
dHt to Int
With the SetOut application, you can set out heights, height differences or distances.
To access the application, press
The Set Out Height screen is displayed first. From this screen, you can access the
screens for setting out height differences or distances.
and the INT softkey.
Back
To exit INT to BS and return to the
foresight/backsight display.
You can enter the point ID of the intermediate point.
Default value is 1001. The point ID is incremented after
each measurement.
The staff reading of the currently measured point.
The distance between the instrument and the interme-
diate point.
The height of the currently measured intermediate point.
The height difference between the currently measured
point and the last backsight point.
The point ID of the last intermediate point. When meas-
uring the first intermediate point, this field remains
empty.
The height difference between the last intermediate
point and the currently measured intermediate point.
When measuring the first intermediate point, this field
remains empty.
and the SetOut softkey.
Softkey
To display further softkeys.
SO dH
To display the Set Out dH screen.
SO Dist
To display the Set Out Distance
screen.
Back
To exit SetOut and return to the fore-
sight/backsight display.