LS10/LS15, Programs
Second Foresight Screen (Station1)
Second Backsight Screen (Station1)
First Backsight Screen (Station2)
The field Stat.ID displays the ID of the next station. In the Backsight/Foresight field,
the first viewing direction of the next station is highlighted in red.
As soon as all measurements of a station are completed you can access the functions
SetOut or INT. For a detailed overview about when these functions are available, refer
to " Availability of the Softkeys SetOut and INT". For a detailed description of the
SetOut and INT functions, refer to "7.2.2 Measurement Procedure for Q-Level".
After finishing all backsight and foresight measurements of a station, the following
three softkeys are available on the screen of the next station:
Station: To show the result screen of the previous station.
Check: To check the height of the last measured point with the height of a known
point (fixpoint).
Close: To start the calculation of the line end.
dH Station: Height difference on the
current instrument station.
Total Dist: Total length of the line.
Distance: Measured distance between
station and staff.
Total dH: Height difference between start
and current backsight.
Height: Height of current backsight.
59