Leica LS10 User Manual page 56

Digital level
Hide thumbs Also See for LS10:
Table of Contents

Advertisement

LS10/LS15, Programs
Field
Description
Max.Distance:
If activated, the instrument monitors the maximum target
distance. If the tolerance is exceeded, a warning message is
displayed. For a detailed description of the warning message,
refer to the next paragraph " Warning Message "Tolerance
exceeded!"".
Change to the Values screen, to enter a value for the maximum
target distance.
Only available for double observation levelling methods such as
Dist B-F :
BFFB. If activated, the instrument monitors the distance balance
between foresight and backsight distance on the current station.
If the tolerance is exceeded, a warning message is displayed. For
a detailed description of the warning message, refer to the next
paragraph " Warning Message "Tolerance exceeded!"".
Change to the Values screen, to enter a value for the distance
balance.
TDist.Bal :
If activated, the instrument monitors the total distance balance
between foresight and backsight distances. If the tolerance is
exceeded, a warning message is displayed. For a detailed descrip-
tion of the warning message, refer to the next paragraph "
Warning Message "Tolerance exceeded!"".
Change to the Values screen, to enter a value for the distance
balance.
If activated, the instrument monitors whether a measurement is
Staff Ends :
within the staff end zones. If the tolerance is exceeded, a warning
message is displayed. For a detailed description of the warning
message, refer to the next paragraph " Warning Message "Toler-
ance exceeded!"".
Change to the Values screen, to enter values for Staff Top and
Staff Bottom.
If activated, the instrument monitors the permitted station differ-
Stn.Diff :
ence. If the tolerance is exceeded, a warning message is
displayed. For a detailed description of the warning message,
refer to the next paragraph " Warning Message "Tolerance
exceeded!"".
Change to the Values screen, to enter a value for the station
difference.
If activated, the instrument monitors the permitted maximum
B-B/F-F :
difference of double observations. If the tolerance is exceeded, a
warning message is displayed. For a detailed description of the
warning message, refer to the next paragraph " Warning Message
"Tolerance exceeded!"".
Change to the Values screen, to enter a value for the maximum
difference.
Only available for the levelling methods SimBF and SimBFFB. If
Turn.Diff :
activated, the instrument monitors whether the height difference
of the two ground points of the staffs is identical for station n in
the foresight measurement and for station n+1 in the backsight
measurements. If the tolerance is exceeded, a warning message is
displayed. For a detailed description of the warning message,
refer to the next paragraph " Warning Message "Tolerance
exceeded!"".
56