Setting a Diagnostic Test as Inactive

Step 3
Step 4
Setting a Diagnostic Test as Inactive
You can set a diagnostic test as inactive. Inactive tests keep their current configuration but do not run at the
scheduled interval.
Use the following command in global configuration mode to set a diagnostic test as inactive:
Command
no diagnostic monitor module slot test
[test-id|name | all]
Cisco Nexus 7000 Series NX-OS System Management Configuration Guide
232
Command or Action
switch(config)# [no] diagnostic
monitor module slot test [test-id
| name | all]
switch(config)# show diagnostic
content module {slot | all}
Purpose
• name—Can be any case-sensitive, alphanumeric string
up to 32 characters.
• hour—The range is from 0 to 23 hours.
• minute—The range is from 0 to 59 minutes.
• second—The range is from 0 to 59 seconds.
Activates the specified test.
The argument ranges are as follows:
• slot—The range is from 1 to 10.
• test-id—The range is from 1 to 14.
• name—Can be any case-sensitive, alphanumeric string
up to 32 characters.
The [no] form of this command inactivates the specified test.
Inactive tests keep their current configuration but do not run
at the scheduled interval.
(Optional)
Displays information about the diagnostics and their attributes.
Purpose
Inactivates the specified test.
The following ranges are valid for the each keyword:
• slot —The range is from 1 to 10.
• test-id —The range is from 1 to 14.
• name —Can be any case-sensitive alphanumeric
string up to 32 characters
Configuring Online Diagnostics