Configuring Online Diagnostics

Configuring Corrective Action

You can configure the device to take corrective action when it detects failures on any of the following runtime
diagnostic tests:
• PortLoopback
• RewriteEngineLoopback
• SnakeLoopback
• StandbyFabricLoopback
This feature enables or disables the corrective, conservative action on all four tests, simultaneously; the
Note
corrective action taken differs for each test.
Before You Begin
Make sure that you are in the correct VDC. To change the VDC, use the switchto vdc command.
Procedure
Step 1
Step 2
Step 3
Command or Action
switch# configure terminal
switch(config)# [no] diagnostic eem
action conservative
switch# event gold [failure-type {sup
| fabric | lc | port}] module {module
| all} test {test-name | test-id}
[severity {major | minor |
moderate}] testing-type {bootup |
monitoring | ondemand | scheduled}
consecutive-failure count
Cisco Nexus 7000 Series NX-OS System Management Configuration Guide
Purpose
Enters global configuration mode.
Enables or disables corrective actions when the system
detects failures on port loopback, rewrite engine loopback,
snake loopback, internal port loopback and standby fabric
loopback tests.
Use the no form of the command to disable these
Note
corrective actions.
Triggers an event if the named online diagnostic test
experiences the configured failure severity for the configured
number of consecutive failures.
The module specifies the number of the module that needs
to be monitored.
The test-name is the name of a configured online diagnostic
test. The test-id specifies the test ID of the event criteria. The
range is from 1 to 30.
The count range is from 1 to 1000.
This CLI command can be used to modify the
Note
consecutive failure count for GOLD system default
policies.
Configuring Corrective Action
233