Configuring Online Diagnostics
Procedure
Step 1
Step 2
Step 3
Step 4

Activating a Diagnostic Test

You can set a diagnostic test as active and optionally modify the interval (in hours, minutes, and seconds) at
which the test runs.
Recommended best practice: Do not change the runtime interval from the default value.
Note
Before You Begin
Make sure that you are in the correct VDC. To change the VDC, use the switchto vdc command.
Procedure
Step 1
Step 2
Command or Action
switch# configure terminal
switch(config)# diagnostic bootup
level {complete | bypass}
switch(config)# show diagnostic
bootup level
switch(config)# copy running-config
startup-config
Command or Action
switch# configure terminal
switch(config)# diagnostic
monitor interval module slot test
[test-id | name | all] hour hour min
minute second second
Cisco Nexus 7000 Series NX-OS System Management Configuration Guide
Purpose
Enters global configuration mode.
Configures the bootup diagnostic level to trigger
diagnostics as follows when the device boots:
• complete—Perform all bootup diagnostics. The
default is complete.
• bypass—Do not perform any bootup diagnostics.
(Optional)
Displays the bootup diagnostic level (bypass or complete)
that is currently in place on the device.
(Optional)
Copies the running configuration to the startup
configuration.
Purpose
Enters global configuration mode.
(Optional)
Configures the interval at which the specified test is run. If no
interval is set, the test runs at the interval set previously, or the
default interval.
The argument ranges are as follows:
• slot—The range is from 1 to 10.
• test-id—The range is from 1 to 14.