Runtime or Health Monitoring Diagnostics

Test Name
EOBCPortLoopback
OBFL
Runtime or Health Monitoring Diagnostics
Runtime diagnostics are also called health monitoring (HM) diagnostics. These diagnostic tests provide
information about the health of a live device. They detect runtime hardware errors, memory errors, the
degradation of hardware modules over time, software faults, and resource exhaustion.
Runtime diagnostics are nondisruptive and run in the background to ensure the health of a device that is
processing live network traffic. You can enable or disable runtime tests. You can change the runtime interval
for a runtime test.
Recommended best practice: Do not change the runtime interval from the default value.
Note
The following tables describe the runtime diagnostic tests for a module and a supervisor.
Table 27: Runtime Diagnostic Tests for Modules
Test Name
ASICRegisterCheck
PrimaryBootROM
SecondaryBootROM
Cisco Nexus 7000 Series NX-OS System Management Configuration Guide
224
Description
Disruptive test, not an
on-demand test. Ethernet
out of band.
Verifies the integrity of
the onboard failure
logging (OBFL) flash.
Description
Default Interval
Checks read/write
1 min
access to scratch
registers for the
ASICs on a
module.
Verifies the
30 min
integrity of the
primary boot
device on a
module.
Verifies the
30 min
integrity of the
secondary boot
device on a
module.
Configuring Online Diagnostics
Supported Modules
Unsupported Modules
Sup1, Sup2, and Sup2E
Sup1, Sup2, and Sup2E
Supported Modules
All modules
All modules
All modules
Unsupported
Modules

Advertisement