Cisco Nexus 7000 Series Configuration Manual page 438

Hide thumbs Also See for Nexus 7000 Series:
Table of Contents

Advertisement

EEM System Policies
Event
__compact_flash
__crypto_device
__eobc_port_loopback
__ethpm_debug_1
__ethpm_debug_2
__ethpm_debug_3
__ethpm_debug_4
__ethpm_link_flap
__external_compact_flash
__lcm_module_failure
__management_port_loopback
__nvram
__pfm_fanabsent_all_systemfan
__pfm_fanbad_all_systemfan
__pfm_fanbad_any_singlefan
__pfm_power_over_budget
__pfm_tempev_major
__pfm_tempev_minor
Cisco Nexus 7000 Series NX-OS System Management Configuration Guide
410
Embedded Event Manager System Events and Configuration Examples
Description
Do CallHome, log error, and disable further HM
testing after 20 consecutive failures of GOLD
"CompactFlash" test
Do CallHome and log error when GOLD
"CryptoDevice" test fails
Do CallHome and log error when GOLD
"EOBCPortLoopback" test fails
Action: none
Action: none
Action: none
Action: none
More than 30 link flaps in a 420-second interval.
Action: Error. Disable the port
Do CallHome, log error, and disable further HM
testing after 20 consecutive failures of GOLD
"ExternalCompactFlash" test
Power cycle two times and then power down
Do CallHome and log error when GOLD
"ManagementPortLoopback" test fails
Do CallHome, log error, and disable further HM
testing after 20 consecutive failures of GOLD
"NVRAM" test
Shuts down if both fan trays (f1 and f2) are absent
for 2 minutes
Syslog when fan goes bad
Syslog when fan goes bad
Syslog warning for insufficient power overbudget
TempSensor Major Threshold. Action: Shutdown
TempSensor Minor Threshold. Action: Syslog