Guidelines And Limitations For F3 Series Module; Guidelines And Limitations For M1/M1Xl Series Modules - Cisco Nexus 7000 Series Configuration Manual

Hide thumbs Also See for Nexus 7000 Series:
Table of Contents

Advertisement

Guidelines and Limitations for F3 Series Module

• For certain rate limit and packet size values on F Series modules, M2 Series modules, and Supervisor
• SPAN sampling is supported only on F Series modules. It is not supported on M Series modules.
• Beginning with Cisco NX-OS Release 6.1, FCoE SPAN on F2 Series modules is supported for storage
• Hardware session 15 is used by NetFlow on F2 and F2e Series modules. Any extended session using
• F2 and F2e Series modules have limited support for rule-based SPAN. They do not support wildcards
Guidelines and Limitations for F3 Series Module
• For certain rate limit and packet size values on F Series modules, M2 Series modules, and Supervisor
• SPAN sampling is supported only on F Series modules.
• Traditional SPAN sessions support traffic from the F Series and M Series modules. Extended SPAN
• Layer 3 multicast egress packets cannot be spanned on F3 Series modules.
• Multiple SPAN destinations are not supported when an F Series module is present in a VDC. If multiple
• MTU truncation and the SPAN rate limit are supported on F Series and M2 Series modules and Supervisor
• A FabricPath core port is not supported as a SPAN destination when an F Series module is present in a
• In Cisco NX-OS Release 6.2, SPAN source functionality on satellite ports and host interface port channels
• In Cisco NX-OS Release 6.2, VLANs containing FEX interfaces can be a SPAN source, but ingress
• F3 Series modules do not support wildcards in the IPv6 source IP filters and the IPv6 destination IP

Guidelines and Limitations for M1/M1XL Series Modules

• SPAN sampling is not supported on M Series modules.
Cisco Nexus 7000 Series NX-OS System Management Configuration Guide
290
2, the SPAN packet rate is less than the configured value because of the internal accounting of packet
sizes and internal headers.
VDCs.
this hardware ID will not span incoming traffic on the F2 and the F2e ports.
in the IPv6 source IP filter and IPv6 destination IP filter. They do not support egress SPAN filtering for
destination MAC addresses and source MAC addresses.
2, the SPAN packet rate is less than the configured value because of the internal accounting of packet
sizes and internal headers.
sessions support traffic only from the F Series and M2 Series modules.
SPAN destinations are configured in a SPAN session, the session is disabled until the F Series module
is powered down or moved to another VDC or the multiple SPAN destinations are reduced to a single
destination
2.
VDC. However, a FabricPath core port can be configured as a SPAN source interface.
is not supported when the FEX is connected to F3 Series modules.
traffic through F3 Series module-based FEX ports cannot be captured.
filters.
Configuring SPAN

Advertisement

Table of Contents
loading

Table of Contents