Hops-Count - HP 5800 series Command Reference Manual

Commands and command syntax options
Hide thumbs Also See for 5800 series:
Table of Contents

Advertisement

View
MPLS LDP view
Default level
2: System level
Parameters
timer: Specifies the LDP recovery time, ranging from 3 to 300 seconds.
Examples
# Set the LDP recovery time to 45 seconds.
<Sysname> system-view
[Sysname] mpls ldp
[Sysname-mpls-ldp] graceful-restart timer recovery 45

hops-count

Description
Use the hops-count command to set the maximum hop count for loop detection.
Use the undo hops-count command to restore the default.
By default, the maximum hop count for loop detection is 32.
The maximum hop count dictates how fast LDP detects a loop. Adjust this parameter as required.
Related commands: loop-detect and path-vectors.
You should configure this command before you enable LDP on any interface.
Syntax
hops-count hop-number
undo hops-count
View
MPLS LDP view, MPLS LDP VPN instance view
Default level
2: System level
Parameters
hop-number: Specifies the hop count, ranging from 1 to 32.
Examples
# Set the maximum hop count for loop detection to 25 for the public network LDP instance.
<Sysname> system-view
[Sysname] mpls ldp
[Sysname-mpls-ldp] hops-count 25
# Set the maximum hop count for loop detection to 25 for LDP instance vpn1.
<Sysname> system-view
[Sysname] mpls ldp vpn-instance vpn1
[Sysname-mpls-ldp-vpn-instance-vpn1] hops-count 25