Section 8
Handling, Serv & Maint
3. Do not operate an alternator on an open circuit. Be sure
all circuit connections are secure.
4. Do not short across or ground any of the terminals on
the alternator or electronic voltage regulator.
5. Do not attempt to polarize an alternator.
6. Do not charge batteries while installed in the airplane.
Refer to the Baron Maintenance Manual for battery
removal and charging procedures.
MAGNETOS
Ordinarily, the magnetos will require only occasional adjust-
ment, lubrication, and breaker point replacement. This work
should be done by a Hawker Beechcraft Corporation Autho-
rized Outlet.
To be safe, treat the magnetos as hot
whenever a switch lead is disconnected at
any point; they do not have an internal
automatic grounding device. Otherwise, all
spark plug leads should be disconnected or
the cable outlet plate on the rear of the
magneto should be removed.
8-26
Model G58
April, 2008