ELECTRICAL SMOKE OR FIRE
Action to be taken must consider existing conditions and
equipment installed:
1. Alternators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .OFF
2. Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .OFF
3. Heading Control . . . . . . MAINTAIN USING STANDBY
The PFD, MFD and Stall Warning will
become inoperative with the batteries and
alternators off. Only the standby instru-
ments will be available.
4. All Electrical Switches . . . . . . . . . . . . . . . . . . . . . . . .OFF
5. Dissipation of smoke may be aided by the following:
a. Cabin Air and Cabin
Heat Controls . . . . . . . . . . . . . . . . . FULL FORWARD
b. Pilot Air and Copilot Air . . . . . . . . . . . . . PULL OPEN
c. Overhead Fresh Air Outlets . . . . . . . . . . . . . . . OPEN
If smoke or fire ceases, individually restore electrical equip-
ment to isolate defective equipment.
6. Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ON
7. Alternators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ON
8. Essential Electrical Equipment . . . . ON ONE AT A TIME
9. Pilot's Storm Window (if required). . . . . . . . . . . . . OPEN
10. Land as soon as practical.