If the red test LED illuminates any time dur-
ing the one minute test, the standby battery
is not sufficiently charged. This may indi-
cate that additional charging is required, or
that the standby battery must be removed
for service or replacement.
All LEDs extinguish after one minute. Thus,
the red LED could illuminate towards the
end of the test period and then extinguish
when the test is complete without the pilot's
knowledge unless the display is continually
monitored.

SHUTDOWN

During a normal shutdown, the Standby Power LED will flash
for approximately one minute after power is removed. No
action is required and the standby attitude indicator will auto-
matically shutdown after the one minute has elapsed. If
desired, the STBY PWR button may be pushed TWICE to
manually turn the indicator off.