5.4.4.3

Dynamic Drive Control

Procedure for application class [2]: Dynamic Drive Control
2.
3.
4.
5.
6.
7.
You have completed quick commissioning.
Converter with the CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2016, FW V4.7 SP6, A5E34259001B AC
Select the I/O configuration to preassign the inverter interfaces.
Default settings of the CU240B-2 interfaces (Page 97)
Default settings of the CU240E-2 interfaces (Page 104)
Set the applicable motor standard and the inverter supply voltage.
Select your motor.
Enter the motor data according to the rating plate of your motor.
If you have selected a motor based on its article number, the data has
already been entered.
Set the most important parameters to suit your application.
Application:
• [0]: Recommended setting for standard applications.
• [1]: Recommended setting for applications with ramp-up and ramp-
down times < 10 s. This setting is not suitable for hoisting gear and
cranes.
• [5] Recommended setting for applications with a high break loose
torque.
Motor identification:
• [1]: Recommended setting. Measure the motor data at standstill and
with the motor rotating. The inverter switches off the motor after the
motor data identification has been completed.
• [2]: Measure the motor data at standstill. The inverter switches off
the motor after the motor data identification has been completed.
Select this setting if the motor cannot freely rotate, e.g. for a
mechanically limited traversing range.
• [3]: Measure the motor data while it is rotating. The inverter switches
off the motor after the motor data identification has been completed.
• [11]: The same setting as [1]. The motor accelerates to the currently
set setpoint after the motor data identification.
• [12]: The same setting as [2]. The motor accelerates to the currently
set setpoint after the motor data identification.
Commissioning
5.4 Quick commissioning with a PC.
155