Table A- 3
New functions and function changes in Firmware 4.7
Function
1
Supporting the identification & maintenance datasets (I&M1 ... 4)
2
Fall in pulse rate with increased drive power required by the motor
The inverter temporarily lowers the pulse frequency if required
•
when the motor is started up, and simultaneously increases the
current limit.
3
S7 communication
Direct data exchange between the inverter and human-machine
•
interface (HMI).
Increase in communication performance with the engineering
•
tools and support of the S7 routing
4
The basic functions of Safety Integrated are unrestrictedly available
in all control types with 1FK7 encoderless permanent-field syn-
chronous motors
5
Direct selection of the 1FK7 encoderless permanent-field synchro-
nous motors using the Article No. with allocated code number
It is not necessary to input individual motor data
•
6
Pulse input as source of setpoint value
The inverter calculates its speed setpoint from a sequence of
•
pulses at the digital input.
7
Dynamic IP address assignment (DHCP) and temporary device
names for PROFINET
8
PROFIenergy Slave profile 2 and 3
9
Uniform behavior for component replacement
After a component is replaced, an inverter with activated Safety
•
Integrated will report what type of component has been re-
placed using a unique code.
10
Improved direct-component control in PM230
Optimized efficiency for pump and fan applications
•
11
Rounding down of BACnet and macros
Converter with the CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2016, FW V4.7 SP6, A5E34259001B AC
A.1 New and extended functions
SINAMICS
G120
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
✓
✓
✓
-
✓
✓
✓
✓
-
✓
✓
✓
-
-
✓
-
-
✓
-
-
-
-
✓
-
-
Appendix
G120D
✓
✓
✓
✓
✓
✓
✓
✓
✓
-
✓
-
-
✓
-
✓
-
-
✓
✓
✓
✓
✓
✓
✓
✓
✓
-
-
-
-
-
-
481