Table 4- 1
Frame size
FSA
FSB
FSC
FSD
FSE
FSF
The Power Modules can be mounted and operated side-by-side. For tolerance reasons, we rec-
1)
ommend a lateral clearance of approx. 1 mm.
62
Mounting dimensions
Width
Height (mm)
1)
(mm)
Total
73
276
100
370
140
432
200
707.5
275
850
305
1107
Shield plate
Power
at the top
Module
---
196
---
292
---
355
83.5
472
122
551
142
708
Converter with the CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2016, FW V4.7 SP6, A5E34259001B AC
Depth (mm)
Shield plate at
the bottom
80
165
78
165
77
165
152
237
177
237
257