Dynamic Drive Control - Siemens SINAMICS G120C USS/MB Operating Instructions Manual

Sinamics g120c series low voltage converter built-in units with frame sizes aa - f
Hide thumbs Also See for SINAMICS G120C USS/MB:
Table of Contents

Advertisement

Commissioning
5.4 Quick commissioning using the BOP-2 operator panel
Motor data identification Select the method which the inverter uses to measure the data of the
connected motor:
● OFF: No motor data identification
● STIL ROT: Measure the motor data at standstill and with the motor rotating.
The inverter switches off the motor after the motor data identification has been completed.
● STILL: Recommended setting: Measure the motor data at standstill.
The inverter switches off the motor after the motor data identification has been completed.
Select this setting if the motor cannot freely rotate, e.g. for a mechanically limited traversing
range.
● ROT: Measure the motor data while the motor is rotating.
The inverter switches off the motor after the motor data identification has been completed.
● ST RT OP: setting same as STIL ROT.
The motor accelerates to the currently set setpoint after the motor data identification.
● STILL OP: setting same as STILL.
The motor accelerates to the currently set setpoint after the motor data identification.
Complete quick commissioning as follows:
1. Switchover the display using an arrow key: nO → YES
2. Press the OK key.
You have completed quick commissioning.
5.4.4

Dynamic Drive Control

Select the motor standard:
● KW 50HZ: IEC
● HP 60HZ: NEMA
● KW 60HZ: IEC 60 Hz
Set the inverter supply voltage.
Select the motor type. If a 5-digit motor code is stamped on the motor rating plate, select the
corresponding motor type with motor code.
Motors without motor code stamped on the rating plate:
● INDUCT: Third-party induction motor
● 1L... IND: 1LE1, 1LG6, 1LA7, 1LA9 induction motors
Motors with motor code stamped on the rating plate:
● 1LE1 IND 100: 1LE1 . 9
● 1PC1 IND: 1PC1
● 1PH8 IND: Induction motor
Depending on the inverter, the motor list in BOP-2 can deviate from the list shown above.
126
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34263257B AF
SINAMICS G120C converter