20 Technical data
20.15 Functions
20.15.1
Controller channels
Number
Controller type
Controller structure
Controller outputs
Disturbance feedforward con-
trol
Autotuning
Sampling rate
a
Ena. variable disturbance permits consideration of influencing variables in the process
environment beyond the actual value alone. This keeps the control response stable, even when
fluctuations in such ambient conditions occur.
20.15.2
Recording function
a
Number of groups
Number of input variables per
group
Recording /
Memory rate
Memory values
Size of the ring buffer
d
History function
Archiving/evaluation
a
A freely configurable set of input variables can be pooled in one group.
Each group has its own display screen. The group affiliation is considered for data storage to enable eval-
uation via PC.
b
The measurement data are stored in a ring buffer. When the ring buffer is full, the recording
function starts to overwrite the measured-value history at the beginning of the ring buffer.
c
This information is based on 4 analog values and 3 binary values, and is provided for orientation.
The total is for both groups.
126
4
Two-state controller
Three-state controllers
Continuous controller
Coarse/fine controller
Modulating controllers
proportional controller with integrated actuator driver
P, PI, PD, PID
For each controller channel, 2 outputs configurable as: pulse
length output, pulse frequency output
(maximal 240 pulses per minute), continuous output
multiplicative and/or additive
step response method
250 ms
Data monitor
2
4× analog
3× digital
1 to 3600 s
Current value
Average value
Minimum value
Maximum value
b
sufficient for 150 entries
No
No
a
Recording function (also
available)
2
4× analog
3× digital
1 to 3600 s
Current value
Average value
Minimum value
Maximum value
c
sufficient for approx. 31 million
c
entries
Yes
Yes (via JUMO PCA3000 evalu-
ation software)