JUMO AQUIS touch S Assembly Instructions Manual page 34

Modular multichannel measuring device for liquid analysis with integrated controller and paperless recorder
Hide thumbs Also See for AQUIS touch S:
Table of Contents

Advertisement

10 Configuration
For JUMO ecoLine O-DO sensors only
Configuration point Selection/
Oxygen unit
Salt content
Air pressure
a
Compensation
Fixed compensation
a
temperature
Compensation tem-
perature
34
setting option
% Sat
mg/l
ppm
0 to 10000 g/kg
500 to 1500 hPa
Fixed compensation temperature
Sensor temperature
Interface
-25 to+150 °C
Selection from Analog selection
Explanation
Selection of the unit in which the ox-
ygen concentration is displayed.
Indication of the salt content (salinity)
of the measurement solution for com-
pensation of the effect of the salinity
on the measured value of the oxygen
concentration in the measurement
solution
Indication of the ambient air pressure
for compensation of the effect of the
air pressure on the measured value
of the oxygen concentration in the
measurement solution
Fixed compensation temperature:
Compensation with a fixed tempera-
ture value that is entered in the con-
figuration item "Compensation
temperature".
Sensor temperature: The integrat-
ed temperature probe of the O-DO
sensor supplies the compensation
temperature.
Interface: The AQUIS touch S trans-
mits the compensation temperature
to the sensor electronics via the inter-
face. The source of the compensa-
tion temperature is set in the
configuration point "Compensation
temperature".
only if "Compensation" is set to
"Fixed compensation tempera-
ture":
constant temperature value, for tem-
perature compensation of the oxy-
gen measurement in the O-DO
sensor
only if "Compensation" is set to
"Interface":
Selection of the signal source from
the Analog selection of the JUMO
AQUIS touch P for temperature com-
pensation of the oxygen measure-
ment in the O-DO sensor

Advertisement