20.14 Housing

geographic height for operation maximum 2000 m above sea level
Case type
Materials
Dimensions
Ambient temperature
Storage temperature
Resistance to climatic condi-
tions
Operating position
Protection type
Closed case
Open case
Cable inlets
Scope of delivery
Standard version
Full configuration kit
(see accessories)
Weight without holder for wall
mounting
(fully configured)
Weight of holder for wall mount-
ing
Installation torques
for cable fittings
Surface-mounted case made of plastic (ABS)
for indoor use only
Terminal compartment cover screws: 1.4567 stainless steel
Mounting plate: 1.4301 stainless steel
301.5 mm × 283.2 mm × 120.5 mm
-5 to +50 °C on device version with voltage supply AC 110 to
240 V
-5 to +45 °C on device version with voltage supply AC/DC 20 to
30 V
-30 to +70 °C
Relative humidity < 92 % annual average, no condensation
any, with due consideration for the viewing angle of the screen
According to DIN EN 60529
IP67
IP20
Cable fittings:
6× M12 × 1.5
3× M16 × 1.5
Cable fittings:
9× M12 × 1.5
2× M16 × 1.5
2× M20 × 1.5
3390 g
790 g
0.7 Nm
2 Nm
2.7 Nm
20 Technical data
for M12 × 1.5
for M16 × 1.5
for M20 × 1.5
125