Asymmetric left
AF5
1
0
AF6
1
0
1 Output signal active
x Actual value
(1) Limit value
Fixed limit value
Asymmetric left
AF7
1
0
AF8
1
0
1 Output signal active
x Actual value
(1) Limit value
Symmetric
(1)
(2)
x
w
(1)
(2)
w
x
Symmetric
1
(2)
0
x
(1)
1
(2)
0
x
(1)
1
(1)
(2)
0
w
1
(1)
(2)
0
w
0 Output signal not active
w Setpoint value
(2) Switching differential
(2)
(1)
(2)
(1)
0 Output signal not active
(2) Switching differential
6 Configuration
Asymmetric right
1
(1)
0
x
w
1
(1)
0
x
w
Asymmetric right
1
0
x
(1)
1
0
x
(1)
(2)
x
(2)
x
(2)
x
(2)
x