Parameter
Syslog Facility Number
[SyslogFacility]
CDR Syslog Sequence
Number
configure system > cdr > cdr-
seq-num
[CDRSyslogSeqNum]
Activity Types to Report via
Activity Log Messages
configure troubleshoot >
activity-log
[ActivityListToLog]
Version 7.2
Note: The device does not increase the debug level to a level that is
higher than what you configured for the 'Debug Level' parameter.
Defines the Facility level (0 through 7) of the device's Syslog
messages, according to RFC 3164. This allows you to identify Syslog
messages generated by the device. This is useful, for example, if you
collect the device's and other equipments' Syslog messages, at one
single server. The device's Syslog messages can easily be identified
and distinguished from other Syslog messages by its Facility level.
Therefore, in addition to filtering Syslog messages according to IP
address, the messages can be filtered according to Facility level.
[16] = (Default) local use 0 (local0)
[17] = local use 1 (local1)
[18] = local use 2 (local2)
[19] = local use 3 (local3)
[20] = local use 4 (local4)
[21] = local use 5 (local5)
[22] = local use 6 (local6)
[23] = local use 7 (local7)
Enables or disables the inclusion of the sequence number (S=) in
CDR Syslog messages.
[0] Disable
[1] Enable (default)
Defines the operations (activities) performed in the Web interface
that are reported to a Syslog server.
[pvc] Parameters Value Change = Changes made on-the-fly to
parameters and tables, and Configuration file load. Note that the
ini file parameter, EnableParametersMonitoring can also be used
to set this option.
[afl] Auxiliary Files Loading = Loading of Auxiliary files.
[dr] Device Reset = Resetting of the device through the
Maintenance Actions page.
Note: For this option to take effect, a device reset is required.
[fb] Flash Memory Burning = Saving configuration with burn to
flash (in the Maintenance Actions page).
[swu] Device Software Update = Software updates (i.e., loading of
cmp file) through the Software Upgrade Wizard.
[ard] Access to Restricted Domains = Access to restricted Web
pages:
(1) ini parameters (AdminPage)
(2) General Security Settings
(3) Configuration File
(5) License Key
(7) Access List
(8) Web User Accounts
[naa] Non-Authorized Access = Attempts to log in to the Web
interface with a false or empty username or password.
[spc] Sensitive Parameters Value Change = Changes made to
"sensitive" parameters:
(1) IP Address