Batch Test Call Scenario: This example describes the configuration of a batch test
call setup for scheduled and continuous call testing of multiple endpoints. The test call
is done between two AudioCodes devices - Device A and Device B - with simulated
test endpoints. This eliminates the need for phone users, who would otherwise need
to answer and end calls many times for batch testing. The calls are initiated from
Device A, where Device B serves as the remote answering endpoint.
Test Call Rules table configuration at Device A:
Test Call Rules table configuration at Device B:
Version 7.2
Figure 52-7: Batch Test Call Example
Endpoint URI: "101"
Called URI: "201"
Route By: Dest Address
Destination Address: "10.13.4.12"
SIP Interface: SIPInterface_0
Call Party: Caller
Maximum Channels for Session: "3" (configures three endpoints - "101",
"102" and "103)
Call Duration: "5" (seconds)
Calls per Sec: "1"
Test Mode: Continuous
Test Duration: "3" (minutes)
Schedule Interval: "180" (minutes)
Endpoint URI: "201"
Maximum Channels for Session: "3" (configures three endpoints - "201",
"202" and "203)
707