AudioCodes Mediant 4000 SBC User Manual page 723

Hide thumbs Also See for Mediant 4000 SBC:
Table of Contents

Advertisement

User's Manual
Parameter
configure system > snmp settings >
sys-oid
[SNMPSysOid]
[SNMPTrapEnterpriseOid]
[acUserInputAlarmDescription]
[acUserInputAlarmSeverity]
[AlarmHistoryTableMaxSize]
configure system > snmp settings >
engine-id
[SNMPEngineIDString]
SNMP Trap Destination Parameters (configure system > snmp trap destination)
Note: Up to five SNMP trap managers can be defined.
SNMP Manager
[SNMPManagerIsUsed_x]
IP Address
ip-address
Version 7.2
55. Configuration Parameters Reference
[1] = Enable
Defines the base product system OID.
The default is eSNMP_AC_PRODUCT_BASE_OID_D.
Note: For the parameter to take effect, a device reset is
required.
Defines the Trap Enterprise OID.
The default is eSNMP_AC_ENTERPRISE_OID.
The inner shift of the trap in the AcTrap subtree is added to
the end of the OID in the parameter.
Note: For the parameter to take effect, a device reset is
required.
Defines the description of the input alarm.
Defines the severity of the input alarm.
Defines the maximum number of rows in the Alarm History
table. The parameter can be controlled by the Config Global
Entry Limit MIB (located in the Notification Log MIB).
The valid range is 50 to 1000. The default is 500.
Note: For the parameter to take effect, a device reset is
required.
Defines the SNMP engine ID for SNMPv2/SNMPv3 agents.
This is used for authenticating a user attempting to access the
SNMP agent on the device.
The ID can be a string of up to 36 characters. The default is
00:00:00:00:00:00:00:00:00:00:00:00 (12 Hex octets
characters). The provided key must be set with 12 Hex values
delimited by a colon (":") in the format xx:xx:...:xx. For
example, 00:11:22:33:44:55:66:77:88:99:aa:bb
Note:
For the parameter to take effect, a device reset is required.
Before setting the parameter, all SNMPv3 users must be
deleted; otherwise, the parameter setting is ignored.
If the supplied key does not pass validation of the 12 Hex
values input or it is set with the default value, the engine
ID is generated according to RFC 3411.
Determines the validity of the parameters (IP address and
port number) of the corresponding SNMP Manager used to
receive SNMP traps.
[0] (Check box cleared) = Disabled (default)
[1] (Check box selected) = Enabled
Defines the IP address of the remote host used as an SNMP
Manager. The device sends SNMP traps to this IP address.
723