AudioCodes Mediant 4000 SBC User Manual page 254

Hide thumbs Also See for Mediant 4000 SBC:
Table of Contents

Advertisement

To configure a Cost Group:
1.
Open the Cost Groups table (Setup menu > Signaling & Media tab > SIP Definitions
folder > Least Cost Routing > Cost Groups).
2.
Click New; the following dialog box appears:
3.
Configure a Cost Group according to the parameters described in the table below.
4.
Click Apply, and then save your settings to flash memory.
Table 15-16: Cost Groups Table Parameter Descriptions
Parameter
Index
[CostGroupTable_Index]
Name
cost-group-name
[CostGroupTable_CostGroupName]
Default Connection Cost
default-connection-cost
[CostGroupTable_DefaultConnectionCost]
Default Minute Cost
default-minute-cost
[CostGroupTable_DefaultMinuteCost]
15.5.2.1.1 Configuring Time Bands for Cost Groups
The Time Band table lets you configure Time Bands per Cost Group. A Time Band defines
a day and time range (e.g., from Saturday 05:00 to Sunday 24:00) and a fixed call
connection charge and call rate per minute for this interval. You can configure up to 70
Time Bands, where up to 21 Time Bands can be assigned to each Cost Group.
User's Manual
Description
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
Defines an arbitrary name to easily identify the row.
The valid value is a string of up to 40 characters.
Note: Each Cost Group must have a unique name.
Defines the call connection cost (added as a fixed charge
to the call) for a call outside the time bands.
The valid value range is 0-65533. The default is 0.
Note: When calculating the cost of a call, if the current
time of the call is not within a time band configured for
the Cost Group, then this default connection cost is used.
Defines the call charge per minute for a call outside the
time bands.
The valid value range is 0-65533. The default is 0.
Note: When calculating the cost of a call, if the current
time of the call is not within a time band configured for
the Cost Group, then this default charge per minute is
used.
254
Mediant 4000 SBC
Document #: LTRT-41729

Advertisement

Table of Contents
loading