Viewing Carrier-Grade Alarms

This section describes how to view SNMP alarms raised by the device.
43.1

Viewing Active Alarms

You can view current (active) alarms in the Web interface that have been raised by the
device. If an alarm is cleared, it is moved into the History Alarms table (see ''Viewing
History Alarms'' on page 624).
Note:
The alarms in the table are deleted upon a device reset.
For more information on SNMP alarms, refer to the SNMP Reference Guide
document.
To view active alarms:
Open the Active Alarms table, by doing one of the following:
Navigation tree: Monitor menu > Monitor tab > Summary folder > Active
Alarms.
Monitor home page: Click the "Alarms" area on the graphical display of the device
(see ''Viewing Device Status on Monitor Page'' on page 618).
Field
Sequential Number
Severity
Source
Description
Date
Version 7.2
Table 43-1: Active Alarms Table Description
The number of the alarm. The alarms are numbered sequentially as they
are raised by the device. The numbering resets to 1 immediately after a
device reset (i.e., the first alarm raised after a reset is assigned the number
#1).
Severity level of the alarm:
Critical (red)
Major (orange)
Minor (yellow)
Component of the device from which the alarm was raised.
Brief description of the alarm.
Date (DD/MM/YYYY) and time (HH:MM:SS) the alarm was raised.