AudioCodes Mediant 4000 SBC User Manual page 459

Hide thumbs Also See for Mediant 4000 SBC:
Table of Contents

Advertisement

User's Manual
2.
Click New; the following dialog box appears:
3.
Configure the Classification rule according to the parameters described in the table
below.
4.
Click Apply.
Table 24-1: Classification Table Parameter Descriptions
Parameter
SRD
srd-name
[Classification_SRDName]
Match
Index
[Classification_Index]
Name
classification-name
[Classification_ClassificationN
ame]
Source SIP Interface
src-sip-interface-name
[Classification_SrcSIPInterfac
eName]
Version 7.2
Figure 24-3: Classification Table - Add Dialog Box
Assigns an SRD to the rule as a matching characteristic for the
incoming SIP dialog.
If only one SRD is configured in the SRDs table, the SRD is
assigned to the rule by default. If multiple SRDs are configured in the
SRDs table, no value is assigned.
To configure SRDs, see ''Configuring SRDs'' on page 309.
Note: The parameter is mandatory.
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
Defines an arbitrary name to easily identify the row.
The valid value is a string of up to 20 characters. By default, no
name is defined.
Note: Each row must be configured with a unique name.
Assigns a SIP Interface to the rule as a matching characteristic for
the incoming SIP dialog.
The default is Any (i.e., all SIP Interfaces belonging to the SRD
assigned to the rule).
Note: The SIP Interface must belong to the SRD assigned to the rule
Description
459
24. Routing SBC
Mediant 4000 SBC

Advertisement

Table of Contents
loading