2. Commissioning
2.8
Parameterisation
Festo P.BE-CPX-PNIO-EN en 1407c English
You can set the reaction of the CPX terminal individually
through parameterisation. The following parameterisation
variants are distinguished:
–
System parameterisation, e.g. deactivation of error mes-
sages, etc.
–
Module parameterisation (module-specific and channel-
specific), e.g. module monitoring, settings for errors, ad-
justment of debouncing times for the inputs, etc.
–
Parameterisation of the diagnostic memory.
A detailed description of the individual parameters as well as
basic principles of application can be found in the CPX system
description (P.BE-CPX-SYS-..).
Parameter lists for the various CPX modules can be found in
the corresponding descriptions for the modules (P.BE-CPX-
EA-..., P.BE-CPX-AX-..., P.BE-CPX-CP-..., etc.).
Note – Module parameter in the operating mode FSU
In the "Fast Start-up" (FSU) operating mode, not all mod-
ule parameters can be set through the control software.
Use the Festo Maintenance Tool (CPX-FMT) or the operator
unit (CPX-MMI) to make the required settings.
System parameters can be set in all operating modes, also
in the FSU operating mode, using the control software.
2-49