2. Commissioning
Pneumatic interface for MPA/
MPA-F and related modules
VPPM proportional-pressure regu-
lation valve (type 32; 2 bar, 6 bar,
10 bar, "not equipped" or vacant
2) 3)
position)
MPA-P Pressure sensor module
(measuring range 0 ... 10 bar)
MPAF-P pneumatic interface with
2) 3) 4)
pressure sensor
Measurement range 0 ... 10 bar)
1)
Module identifier in the operator unit or in the hardware configuration of the programming software
2
) No support for the additional function FSU
Note
When using the module in FSU operation, fast running up of the CPX terminal and compliance of
the PROFINET specification with regard to FSU are not guaranteed.
3)
Pneumatic modules of type MPA-P or MPAF-P and VPPM are among the analogue modules:
Observe the sequence of the modules as part of addressing or in I/O mapping (see Tab. 2/9)
4)
MPAF-P is also called "end plate" with pressure sensor or pressure sensor plate
Tab. 2/6:
Overview of CPX pneumatic interfaces and pneumatic modules (part 2)
Festo P.BE-CPX-PNIO-EN en 1407c English
Module type
(Name)
VPPM-6...-1-...
[2AI/2AO]
2) 3)
VMPA...-FB-PS-...
[2AI-P]
VMPAF-FB-EPL-PS
[1AI-P]
Module
Allocated address
1)
indicator
space
Inputs
VPPM
1 word/
Proportional
16 I
valve ...
MPA-P
1 word/
Analogue in-
16 I
put press.
MPAF-P
1 word/
Analogue in-
16 I
put press.
Outputs
1 word/
16 O
2-13