1. Installation

1.6.4 Network interface of the CPX-M-FB34

Socket
RJ45, push-pull
Tab. 1/8:
Pin allocation of the network interfaces of the CPX-M-FB34 (RJ45)
Festo P.BE-CPX-PNIO-EN en 1407c English
There are two RJ45 push-pull sockets (AIDA-compliant) on the
CPX-M-FB34 for the network connection:
Pin
Signal
1
TD+
2
TD–
3
RD+
4
n.c.
5
n.c.
6
RD–
7
n.c.
8
n.c.
Housing
Shield/FE
Connection with plug from Festo
Connect the CPX terminal to the network with a Festo plug
FBS-RJ45-PP-GS. The plug is designed for Ethernet cable with
cable diameter of 5 ... ... 8 mm.
To achieve the required degree of protection, e.g. IP65/IP67:
Use Festo plugs.
Seal unused connections (see section 1.7).
Explanation
Transmission data (transmit data, TD) +
Transmitted data –
Receive data (receive data, RD) +
Not connected
Not connected
Received data –
Not connected
Not connected
Shield/functional earth (FE)