Error code
EMERGENCY. Is generated when low kit
drive receives a software emergency signal
19/EM
that is not accompanied by a hardware
emergency signal
LOW KIT DRIVER COVER PLATE FAN.
This error is genereted if there is a
20/SFAn
mulfunction on the fan mounted on the
driver's cover plate, for at least 5 sec.
LOW KIT DRIVER INTERNAL FAN. This
error is genereted if there is a mulfunction on
21/PFAn
the internal low kit driver fan, for at least 5
sec
INVERTER POWER SUPPLY: This error is
generated if a voltage <156 VAC for at least
22/IMV
1 sec. when the AC motor is working or for
at least 10 sec. when AC motor is not
working.
SHORT CIRCUIT. Is generated in the event
23/SHC
of a short circuit between a motor phase and
earth.
OVERHEATING of the dissipator sensor:
24/OHS
This error is genereted if a mulfunction of
the dissipator sensor last more than 1 sec.
Description
Possible solution
-
low kit driver
cover plate fan
low kit driver
internal fan
-
Check the belt motor
low kit d
river
Page 6.13