RUN PERSONAL: Service & maintenance manual - rev. 3.1
"GRADIENT NOT
WORKING" MESSAGE
ON THE DISPLAY
Verify the P09
parameter is correctly
1
setted.
2
NO
Replace the
The micro working properly?
microswitch.
NO
SI
3
Replace the slope
NO
Setting P09=0,
SI
Verify if the voltage gardient of
engine
turn off and on the machine.
the engine during the reset.
and
The motor moves
There is tension?
re-setting the P09=15
(activates the splope)?
parameter.
SI
NO
Replace the Driver
Verify during the movement, if
and
the impulse are present on the
re-setting the P09=15
J7 connector of the Driver
parameter.
Board.
NO
Replace the Driver
and
re-setting the P09=15
parameter.
Page 6.16