Technical Manual
Function
Three-phase directional overcurrent protection that
contains three independent phase-segregated timers,
low stage, instance 2
Three-phase directional overcurrent protection that
contains three independent phase-segregated timers,
high stage, instance 1
Three-phase directional overcurrent protection that
contains three independent phase-segregated timers,
high stage, instance 2
Non-directional earth-fault protection, low stage,
instance 1
Non-directional earth-fault protection, low stage,
instance 2
Non-directional earth-fault protection, high stage,
instance 1
Non-directional earth-fault protection, high stage,
instance 2
Non-directional earth-fault protection, instantaneous
stage
Directional earth-fault protection, low stage, instance 1
Directional earth-fault protection, low stage, instance 2
Directional earth-fault protection, high stage
Admittance based earth-fault protection, instance 1
Admittance based earth-fault protection, instance 2
Admittance based earth-fault protection, instance 3
Transient/intermittent earth-fault protection
Harmonics based earth-fault protection
Non-directional (cross-country) earth fault protection,
using calculated Io
Negative-sequence overcurrent protection, instance 1
Negative-sequence overcurrent protection, instance 2
Negative-sequence overcurrent protection, instance 3
Negative-sequence overcurrent protection, instance 4
Phase discontinuity protection
Residual overvoltage protection, instance 1
Residual overvoltage protection, instance 2
Residual overvoltage protection, instance 3
Three-phase undervoltage protection, instance 1
Three-phase undervoltage protection, instance 2
Three-phase undervoltage protection, instance 3
Three-phase overvoltage protection, instance 1
Three-phase overvoltage protection, instance 2
Three-phase overvoltage protection, instance 3
Positive-sequence undervoltage protection, instance 1
Positive-sequence undervoltage protection, instance 2
Negative-sequence overvoltage protection, instance 1
Negative-sequence overvoltage protection, instance 2
Frequency protection, instance 1
Frequency protection, instance 2
Frequency protection, instance 3
Frequency protection, instance 4
Frequency protection, instance 5
Frequency protection, instance 6
Three-phase thermal protection for feeders, cables
and distribution transformers
Three-phase thermal overload protection for power
transformers, two time constants
Table continues on next page
IEC 61850
DPH3LPDOC2
DPH3HPDOC1
DPH3HPDOC2
EFLPTOC1
EFLPTOC2
EFHPTOC1
EFHPTOC2
EFIPTOC1
DEFLPDEF1
DEFLPDEF2
DEFHPDEF1
EFPADM1
EFPADM2
EFPADM3
INTRPTEF1
1)
HAEFPTOC1
EFHPTOC1
NSPTOC1
NSPTOC2
NSPTOC3
NSPTOC4
PDNSPTOC1
ROVPTOV1
ROVPTOV2
ROVPTOV3
PHPTUV1
PHPTUV2
PHPTUV3
PHPTOV1
PHPTOV2
PHPTOV3
PSPTUV1
PSPTUV2
NSPTOV1
NSPTOV2
FRPFRQ1
FRPFRQ2
FRPFRQ3
FRPFRQ4
FRPFRQ5
FRPFRQ6
T1PTTR1
T2PTTR1
Section 1
Introduction
IEC 60617
IEC-ANSI
3I> -> (2)
67-1 (2)
3I>> -> (1)
67-2 (1)
3I>> -> (2)
67-2 (2)
Io> (1)
51N-1 (1)
Io> (2)
51N-1 (2)
Io>> (1)
51N-2 (1)
Io>> (2)
51N-2 (2)
Io>>>
50N/51N
Io> -> (1)
67N-1 (1)
Io> -> (2)
67N-1 (2)
Io>> ->
67N-2
Yo> -> (1)
21YN (1)
Yo> -> (2)
21YN (2)
Yo> -> (3)
21YN (3)
Io> -> IEF
67NIEF
Io>HA
51NHA
Io>> (1)
51N-2 (1)
I2> (1)
46 (1)
I2> (2)
46 (2)
I2> (3)
46 (3)
I2> (4)
46 (4)
I2/I1>
46PD
Uo> (1)
59G (1)
Uo> (2)
59G (2)
Uo> (3)
59G (3)
3U< (1)
27 (1)
3U< (2)
27 (2)
3U< (3)
27 (3)
3U> (1)
59 (1)
3U> (2)
59 (2)
3U> (3)
59 (3)
U1< (1)
47U+ (1)
U1< (2)
47U+ (2)
U2> (1)
47O- (1)
U2> (2)
47O- (2)
f>/f<,df/dt (1)
81 (1)
f>/f<,df/dt (2)
81 (2)
f>/f<,df/dt (3)
81 (3)
f>/f<,df/dt (4)
81 (4)
f>/f<,df/dt (5)
81 (5)
f>/f<,df/dt (6)
81 (6)
3Ith>F
49F
3Ith>T
49T
29