Planet WGSW-28040 Command Manual page 325

Managed 28-port switch
Hide thumbs Also See for WGSW-28040:
Table of Contents

Advertisement

clock timezone ACRONYM HOUR-OFFSET [minutes <0-59>]
no clock timezone
Parameter:
ACRONYM
HOUR-OFFSET
minutes <0-59>
Default:
Default time zone is UTC+8.
Mode:
Global Configuration
Usage Guide:
Use the clock timezone command to set timezone setting. Use the no form of this command to default setting.
Example:
The example shows how to set time zone of switch and then restore to default time zone. You can verify settings by
the following show show clock command.
switch(config)# clock timezone test +5
switch(config)# show clock detail
10:13:27 test(UTC+5) Sep 21 2012
No time source
Time zone:
Acronym is test
Offset is UTC+5
switch(config)# no clock timezone
switch(config)# show clock detail
13:14:50 DFL(UTC+8) Sep 21 2012
No time source
Time zone:
Acronym is DFL
Offset is UTC+8
Specify acronym name of time zone
Specify hour offset of time zone
Specify minute offset of time zone
Command Guide of WGSW-28040