Logging service is enabled
TARGET | STATUS | Server (PORT) | FACILITY | LOG LEVEL
----------+----------+---------------------------------+----------+----------------------------------
buffered | enabled | | |emerg, alert, crit, error, warning, notice, info

4.14.2 logging flash | buffered

Command:
logging (flash|buffered) [severity <0-7>]
no logging (flash|buffered)
Parameter:
flash
buffer
severity
Default:
Severity = 6 (emerg, alert, crit, error, warning, notice, info)
Mode:
Global Configuration
Usage Guide:
Enable/Disable the local capability to log message to RAM/flash with the minimum severity. The minimum severity
value is "6", including messages of severity emergency, alert, critical, error, warning, notice, and info.
logging flash
Enable the capability to log message to flash, and the default minimum severity is 6. When the service is enables,
messages will start to be logged to the flash. All logging messages will be saved when the system shutdown. Only
when the local logging capability of flash is enabled, the status of logging flash service will be shown by the command
"show logging".
logging buffered
Enable the capability to log message to RAM, and the default minimum severity is 6. When the service is enabled, the
messages will start to be logged to RAM. All logging message will be lost when the system shutdown.
no logging flash
Specify logging to flash.
Specify logging to RAM.
Specify the minimum severity mask of logging message.