4.2 SERVICE PROGRAM MODE
4.2.1 SERVICE PROGRAM MODE OPERATION
The service program (SP) mode is used to check electrical data, change modes,
and adjust values.
Service Program Access Procedure
Entering SP mode
1) Press the following keys in sequence.
#→.→-→4→$
NOTE: Hold the $ key for more than 3 seconds.
2) A menu of SP modes is displayed on the LCD.
S P M o d e
1. Copy
Ver 13. 1. 5 na
NOTE: 1) The installed applications appear as 1. Copy, 2. Fax, 3. Printer, If an
application is not installed, the application name will not appear.
2) The meaning of the bottom line is as follows.
• "Ver 13.1.5 na" is the BICU board software version.
[Serviceman]
SP-Mode Class 1 No. Select
Class 1 No. <Feed
↑Prev.
3) Press the number for the application which you need (e.g. press "1" for
copier). Then, the application's SP mode display will appear, as shown.
Exiting SP mode
1) Press the "Back" and "Exit" keys until the standby mode display appears.
SM
Select number
2. Fax
3.
S P - X X X X - X X X
>
↓Next
O K
4-5
SERVICE PROGRAM MODE
Exit
A321M501.WMF
Exit
A321M500.WMF
A230/A231/A232