4.5 SERVICE PROGRAM MODE

The service program (SP) mode is used to check electrical data, change modes, or
change adjustment values.

4.5.1 ACCESS PROCEDURE

Service Program Mode Access Procedure (For Engineers)
1. Press the following keys on the operation panel in the following order:
Clear Modes ⇒ ⇒ ⇒ ⇒ 1 ⇒ ⇒ ⇒ ⇒ 0 ⇒ ⇒ ⇒ ⇒ 7 ⇒ ⇒ ⇒ ⇒ Clear/Stop
*: Hold down the Clear/Stop key for more than 3 seconds.
2. The following is displayed on the LCD when the SP mode is accessed.
3. Using the number keys, enter the desired Main Menu Number (listed below
and in the service program table), then press the OK key on the bottom of the
LCD (or the Enter (#) key).
klqbW= The main menu number can be shifted up or down by pressing the
klqbW=
klqbW=
klqbW=
Prev. or Next key [A] on the bottom of the LCD.
Main Menu Numbers List
1.Data Logging
2.Basic Settings
3.User Custom Settings
4.Input Test Mode
5.Output Test Mode
6.System Adjustment
7.Memory Data Clear
8.System Test
SERVICE PROGRAM MODE