3.19 ANTI-CONDENSATION HEATER
[B]
[A]
CAUTION
Unplug the machine power cord before starting the following procedure.
1. Remove the exposure glass, scanner rear cover, and stand rear cover (see
Interchange Unit Installation for the stand rear cover).
2. Remove the rear cover and upper left cover.
3. Move the 1st and 2nd scanners to the right.
4. Install the harness clamp [A].
5. Install the anti-condensation heater [B] (2 screws).
NOTE: The heater harness should be routed under the harness guard [C].
6. Install the harness clamp [D].
7. Connect the connector [E] to the heater, then secure the grounding wire [F] (1
screw).
SM
ANTI-CONDENSATION HEATER
[C]
A231I519.WMF
[D]
[E]
3-63
[F]
A231I520.WMF
A230/A231/A232