Supply Harmonic Analysis Frames 1, 2 & 3 (230V Filtered) - Parker 650G Product Manual

Frame 1, 2, 3 & c - f
Hide thumbs Also See for 650G:
Table of Contents

Advertisement

9-16
Technical Specifications
Supply Harmonic Analysis Frames 1, 2 & 3 (230V filtered)
Assumptions:
THD(V) x 100 
where Q
The results conform to stage 1 and stage 2 of the Engineering Recommendation G.5/4 February 2001,
Classification 'C': Limits for Harmonics in the UK Electricity Industry
Drive Type
Motor Power (kW)
Fundamental Voltage (V)
Typical Motor Efficiency %
Harmonic No.
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
40
Total RMS Current (A)
THD (V) %
(Short circuit fault to Neutral)
5kA short circuit supply capability at 230V 1, equivalent to 146H supply impedance
7.5kA short circuit supply capability at 230V 3, equivalent to 56H supply impedance
10
kA short circuit supply capability at 400V 3, equivalent to 73H supply impedance
is the rated rms value of the fundamental voltage of the supply transformer.
1n
0.25
0.37
0.55
230
230
230
85
85
85
7.4
7.5
7.8
1.4
0.2
1.9
2.9
0.4
4.4
1.1
0.5
1.9
0.2
0.2
0.2
0.1
0.1
0.2
0.0
0.1
0.1
0.1
0.0
0.1
0.0
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
8.2
7.5
9.3
0.3559
0.0972
0.5426
www.comoso.com
h 2
 Q
h 2
%
h 40
Q
1n
650G
0.75
1.1
1.5
230
230
230
85
85
RMS Current (A)
8.2
9.0
10.3
2.2
2.9
3.9
4.6
4.8
5.2
2.0
2.3
2.5
0.3
0.4
0.4
0.2
0.2
0.3
0.1
0.1
0.1
0.1
0.1
0.1
0.0
0.0
0.1
0.0
0.0
0.1
0.0
0.0
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
9.9
10.9
12.5
0.5733
0.6277
0.7055
.
2.2
3.0
230
230
85
85
85
TBA
TBA
650G AC Drive
4.0
230
85
TBA