Parker 650G Product Manual page 74

Frame 1, 2, 3 & c - f
Hide thumbs Also See for 650G:
Table of Contents

Advertisement

6-11
Programming Your Application
MMI Parameters Table
Display
Parameter
ENABLED KEYS
F
Parameter Setting RUN
0000
0010
0020
0030
0040
0050
0060
6901
0070
0080
0090
00A0
00B0
00C0
00D0
00E0
6911
00F0
6511
6521
APPLICATION
LOCK
F
DETAILED MENUS Selects Full menu detail when TRUE. The additional
ENC MODE
F
ENC RESET
F
ENC INVERT
F
ENC LINES
F
Description
The following keys on the 6901 keypad can be
enabled or disabled separately. The combination
produces the parameter setting as in the table
below. The default of FFFF enables all keys.
L/R
JOG
-
-
-
-
-
-
-
-
ENABLED
-
-
ENABLED
-
ENABLED
-
-
ENABLED
-
-
ENABLED
ENABLED
-
ENABLED
ENABLED
ENABLED
-
-
ENABLED
-
-
ENABLED
-
ENABLED
ENABLED
-
ENABLED
ENABLED
ENABLED
-
ENABLED
ENABLED
-
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
When using the standard 6511 and 6521 keypad,
disabling the DIR key prevents the local setpoint
going negative (for reverse). Similarly, disabling
the L/R key prevents the drive being changed from
Local to Remote, or Remote to Local modes.
Setting this parameter to TRUE prevents editing of
parameter
P
1.
Set this parameter to FALSE to edit parameter
parameters in the Full menus are indicated in this
table by
F
SET::ENC Menu
Set this parameter to
the requirements for
your encoder:
0 : QUADRATURE (using digital inputs 6 & 7,
ENCA and ENCB respectively)
1 : CLOCK/DIR (using digital inputs 6 & 7,
ENCA and ENCB respectively)
2 : CLOCK (using digital input 6, ENCA)
When TRUE the POSITION and SPEED
outputs are set (and held) at zero.
When TRUE, changes the sign of the
measured speed and the direction of the
position count.
The number of lines must be set to match the
type of encoder being used. Incorrect setting
of this parameter will result in an erroneous
speed measurement.
www.comoso.com
Range
0000 to FFFF
DIR
-
ENABLED
-
ENABLED
-
ENABLED
-
ENABLED
-
ENABLED
-
ENABLED
-
ENABLED
-
ENABLED
0=FALSE
1=TRUE
P
1.
0=FALSE
1=TRUE
0= QUADRATURE
1= CLOCK/DIR
2= CLOCK
0=FALSE
1=TRUE
0=FALSE
1=TRUE
100 to 10000
Default
FFFF
0
0
0
0
0
100
650G AC Drive

Advertisement

Table of Contents
loading

Table of Contents